DOCUMENT LIBRARY

RESOURCES

Find answers about panel installation, download the catalogue or request technical documents.

Acoustic slat panel installation FAQ

For interior wall installations using wood slats on a PET felt backing.

Walls and layout

Can I install the panels on drywall, plywood or masonry?

Drywall and plywood are suitable starting surfaces when the wall is flat and secure. On drywall, plan the fixing points around the studs or use anchors rated for the wall and panel load. For concrete or masonry, ask your installer to specify a suitable backing and fixing method before mounting the panels.

Does the panel need to acclimate before installation?

For these felt-backed panels in a dry, finished interior, a separate acclimation period or routine moisture check on each panel is generally unnecessary. If the wall is damp, wet work is still drying, or the panels have arrived from very different conditions, confirm the site conditions before fixing them.

Where should I start the first panel?

Measure the wall and work out the width of the last panel first. Start at either end. For vertical slats, mark a plumb line with a level and align the first panel to it. Check the next panel against that line and the spacing of the slats.

Screws and adhesive

Should I use screws, adhesive or both?

Use screws as the primary fixing. Position them in the gaps between the wood slats and drive them through the PET felt into the planned fixing points. Distribute the fixings on both sides near the top, middle and bottom. A compatible construction adhesive can supplement the screws.

What screw length and spacing should I use?

Our showroom wall used 30 mm (about 1 3/16 in.) screws. For a panel 2,600 mm tall and 320 mm wide, the example layout spaces the fixing points approximately 800 mm (31½ in.) vertically and 160 mm (6¼ in.) horizontally. Have your installer choose the length and layout for your actual panel, backing and anchors.

Which adhesive should I use, and where does it go?

Choose a construction adhesive whose label lists both the felt backing and the wall surface as suitable materials. Apply it to the back of the PET felt and follow the adhesive maker’s directions for coverage and curing. SEE VENEER has no specific tested brand or model to recommend.

Applying adhesive to the back of a loose panel
Supplementary adhesive on the backing before the panel is fixed to the wall.

Cuts and panel joints

How can I get a clean cut through the wood slats?

Support the panel on a work surface and test the cut on an offcut. Use a circular saw with a blade suited to veneered MDF. Follow the tool and blade instructions for which face goes up. Wear eye protection and use dust control when cutting or sanding. Lightly sand the cut edge with progressively finer paper, keeping the abrasive off the veneer face.

How do I trim the last panel to width?

Measure the remaining width at several heights. If the cut falls between two slats, trim the exposed felt with a sharp utility knife on a cutting surface. If it crosses a wood slat, cut the veneered MDF with a suitable saw, then trim any remaining felt separately.

Should I leave a gap between adjacent panels?

Bring the adjoining panel edges together so the slat spacing continues across the joint. Check the joint before fixing the next panel. This applies to the panel-to-panel seam. Follow the project detail at perimeters and existing building movement joints.

Corners, edges and outlets

How do I finish an inside corner, an outside corner or an exposed edge?

Dry-fit both sides of the corner first. SEE VENEER offers edge trims and veneer edging for visible cuts. Select the trim before deciding how to fix it. Top and bottom edges can often finish directly against an adjoining surface when it conceals the cut.

How should I plan a cutout for an outlet or switch?

Measure the electrical box and transfer its position to the loose panel. Cut the opening on a work surface with an appropriate router or cutout tool. Have a qualified electrician isolate the circuit, verify it is de-energized and handle any changes to the box or device depth for the new wall finish.

Where can I explore application ideas or request a guide for my wall?

Browse the gallery for product and interior application ideas. When requesting a guide, tell us the panel name, wall material and panel dimensions. Mention any corners, outlets or exposed edges you would like the guide to cover.

DOWNLOADS & DOCUMENT REQUESTS

PRODUCT & TECHNICAL LITERATURE

Select the information you need and share your project details. Our team can check which current documents are available for your selected product and application.

SEE COLOR terracotta catalogue interior reference

SEE COLOR / DYED NATURAL WOOD VENEER

Colour, with the
warmth of real wood.

Explore eight colours, three formats, product galleries, grain details and interior references.

EXPLORE SEE COLOR →
DOWNLOAD CATALOGUE · ENGLISH PDF · 27 PAGES ↓